INSTRUCTION

Step 1

Reove the three bolts on the injection pump as shown in the picture.

 Instruction to install a slenoid

Step 2

Remove the manual stopping lever and remove the spring inside the small cover.

 Instruction to install a slenoid

Step 3

Install stopping lever plate. The installation direction is as shown in the following picture. pointy pole up.

 Instruction to install a slenoid

Step 4

Hook up Solenoid.

 Instruction to install a slenoid

Step 5

Connect the stopping pole and the lever piece.

 Instruction to install a slenoid

Step 6

Adjust the length of adjustment lever. Making it right length for stopping when retraction.

 Instruction to install a slenoid

Step 7

Connect cable harness of solenoid with that from the engine control box.

 Instruction to install a slenoid

Step 7 can precede Step 6